Wavecom Instruments Fully Integrated Test n Print Unit User Manual
21
TnP-500 (X)® Series extra features
Meter Mode ® - (Independent of all other Tests)
How to activate Meter Mode
Hold F3 from main screen display for 2 seconds
Screen will change to show volts by default when socket is ( not powered )
Plug appliance into testers , test socket , Press F3 to go into power mode and will show ( Warning
device will be powered )
Press F3 again to continue and (power the device). If you continue the A-N LED on the tester will flash
green and device will power up. Otherwise press enter to exit.
Press the enter key to stop the power mode and return to volts.
Pressing F3 key will start power mode again.
TnP stays in Meter Mode regardless of power on/off until you exit
Pressing Enter key will exit meter mode and return the main menu.
If the TnP is reset in meter mode it will return to meter mode when powered up again.
Meter Mode Uses
Meter Mode is a new and versatile function that will allow you to display Electrical Parameters from a Power
outlet source or from the appliance under test.
Typical Applications
Example.: Measuring the Power of a bar heater, or electric power drill check the ratings and compare them to
that on the compliance plate etc. Quick test of Power outlet Voltages in rooms or locations split from multiple
circuits.
Meter Mode Features (Four Discrete Options)
Electrical parameters are displayed as Volts, Amps, Watts, and Volt / Amps
These electrical parameters will be displayed on the Testers main screen display. Select from the 4 Test
available in Meter Mode.
Meter Mode Measures and displays volts in AC, Current in Amps, Power Measurement in Watts and VA in