Leakage Test Time
The leakage test time is USER adjustable. You may need to adjust timing in this feature if the DUT has a long
power up time or requires special power on procedure. Default time for Leakage Test is 20 seconds. From this
menu you can change the test time from 5 seconds to 28800 seconds. Adjusting to any less than 5 seconds will
put the test time to infinite.
Press the key to increase the test time.
Press the key to decrease the time.
Press the key to set the new leakage / power test time.
Press the key to escape out of the menu. No changes saved.
Audio Option - All TnP models
Enabling the audio option will make the TnP use a sound to indicate a pass or a fail at the end of a test. If the
TnP unit has never been altered then the audio beep is disabled.
Press the key to disable.
Press the key to enable.
Result Hold time option - all TnP models
Note Carefully: This setting will change the default display times and will remain until user re-sets to another
preferred value.
The feature enables the user to change the displayed time of the Test Result from approx. 1 – 90 seconds.
To enable Result Hold time option, from Main menu A, hold ENTER key and press F2 key. Release ENTER
key. Further pressing F2 key four times cycles you to the Result Hold setting screen. Pressing ENTER key (OK)
will display the settings page. Select your preferred timing by pressing F2 or F3 buttons ( Increase or Decrease)
as observed on the LCD screen.
Once the required result is shown on the LCD screen, press the ENTER key to lock new Result Hold time. The
TnP-500 will return to Main menu A.
Please note: as a further convenience, if Result Hold time during normal testing needs to be reduced, simply
press the ENTER key to rapidly move to the next test sequence. Alternative, is to re-set the Result Hold setting
again, as above.
Label Options - Only on Selected Memory Models
Changing the label options changes the way the printer behaves or how the tag is printed. When selecting this
option you will be prompted with 3 different options. Enable / Disable, Choosing a label set and modify the due
date.
Enable / Disable
Selecting this option will enable or disable the tag information being sent to the zebra printer. The printer can
also be disabled by switching the printer off from the power switch located on the side of the printer. Once the
printer is switched back on it will not print out the records that were created while the printer was switched off.
Press the key to disable.
Press the key to enable.