7.8. Default configuration Z
Restores the configuration profile.
Application to GSM ATZ
GSM to application OK command valid
7.9. DTE-DCE local flow control +IFC
This command is used to control the operation of local flow control
between the DTE and DCE.
AT+IFC=<DCE_by_DTE>,<DTE_by_DCE>
* < DCE_by_DTE > :
0 none not supported
1 Xon/Xoff local circuit 103 not supported
2 RTS supported
3 Xon/Xoff global on circuit 103 not supported
* < DTE_by_DCE > :
0 none not supported
1 Xon/Xoff circuit 104 not supported
2 CTS supported
Application to GSM AT+IFC?
GSM to application +IFC: 2,2
OK
current values
Application to GSM AT+IFC=?
GSM to application +IFC: (0-3),(0-2)
OK
possible values.
Application to GSM AT+IFC=0,0
GSM to application OK new values
7.10. Set DCD signal &C
This commands controls the Data Carrier Detect (DCD) signal.