SAFETY INSTRUCTIONS
This meter has been designed for safe use, but must be operated with caution. The rules
listed below must be carefully followed for safe operation.
1. NEVER apply voltage or current to the meter that exceeds the specified maximum:
500mA 1000V fast acting fuse
10A 1000V fast acting fuse (20A for 30
seconds max every 15 minutes)
Frequency, Resistance,
Capacitance, Diode Test, Continuity
Surge Protection: 8kV peak per IEC 61010
2. USE EXTREME CAUTION when working with high voltages.
3. DO NOT measure voltage if the voltage on the "COM" input jack exceeds 600V
above earth ground.
4. NEVER connect the meter leads across a voltage source while the function switch
is in the current, resistance, or diode mode. Doing so can damage the meter.
5. ALWAYS discharge filter capacitors in power supplies and disconnect the power
when making resistance or diode tests.
6. ALWAYS turn off the power and disconnect the test leads before opening the
covers to replace the fuse or batteries.
7. NEVER operate the meter unless the back cover and the battery and fuse covers
are in place and fastened securely.
8. If the equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.